ELM System - Power Supply Units

Ordering designations: 3000-U03-XX

Abstract

This Power supply unit can supply one or several modules of an ELM system. For large systems with many modules or great distances between modules several power supply units are recommended. Some of the ELM module-types provide explicit connections for power supply units and can therefore act as a power feeding point for the ELM system. The other module types are normally supplied by these modules by means of the CAN Bus cable connection.

 

The following module-types provide explicit connections for power supply:

 

Hardware designation (without equipping)

Ordering designations

H1m11v1

3000-U11-00/02

3000-U12-00/02

H1m11v2

3000-U11-00/02

3000-U12-00/02

3000-U32-00/02

3000-U33-00/02

H1m13v1

3000-U13-00/02

H1m15v1

3000-U09-00/02

 

Versions of 12V cable connection
3000-U03-00
The connection cable is intended for single wire connections to unencapsulated modules of housing version "KIT" (-00).
3000-U03-02
The connection cable is equipped with a specified plug for connecting encased modules of housing version "BOX" (-02).

 

See also (information becomes more general downwards):
Components - Overview
ELM system - Overview

 

Housing/Plug-versions

Technical Data

Input voltage

100...240 VAC

Frequency

50..60Hz

Output voltage

12 VDC

Output voltage tolerance

+/-5% at full load

Efficiency

70% typical at full load

Output current max. 700 mA

Operating temperature

0° C to 40° C at maximum load

Storage temperature -40° C to 70° C
Humidity 5% to 95% non condensing
Input Transient Susceptibility Complies with IEC 61000 requirements
Standards IEC 60950 und UL 1950
MTBF calculation 200,000 hours at maximum load levels and an ambient tenperature of 25° C (in correspondence with MIL-HDBK-217)

 

Connector/Cable

Signal

Wire Color
+12 VDC Black
Ground White

 

Dimensions