ELM System - Cables

Ordering designations: 3000-U17, 3000-U18, 3000-U19, 3000-U28, 3000-U29, other on inquiry

Overview

Several cables are available for connecting ELM system devices and accessories.

 

Cable used for

(Click on a link for a detailed description.)

Ordering designations
CAN/Power cable for connecting "KIT"-modules 3000-U17, 3000-U18, 3000-U19
CAN/Power cable for connecting "KIT"-modules to "BOX"-modules or to 19 inch Racks on inquiry
Patch-Cable Straight-Through 2x RJ45 for CAN-connection of 19'' racks on inquiry
Prolongation cable for peripherals of "BOX"-modules or 19'' racks on inquiry
Y-Splitter cables for connecting 2 sensors/actors to a 19 inch Rack on inquiry
Cable for connecting a Communication Component directly to a PC/Workstation via Ethernet-LAN 3000-U28
Cable for connecting a Communication Component to a Ethernet-Hub/Switch   on inquiry
RS232 cable for connecting a Communication Component to a workstation 3000-U29

 

 

See also (information becomes more general downwards):
Components - Overview
ELM system - Overview

 

Cables in particular

CAN/Power cable for connecting "KIT"-modules

 

 

Cable with CAN-plugs (ZH-plugs) at both ends for connecting two "KIT"-housing versions of ELM modules. The cable is for CAN-Bus signal transmission as well as for power supply. Several standard lengths are available. Other lengths on demand.

Ordering designation  (0,20 meters): 3000-U17

Ordering designation  (3,00 meters): 3000-U18

Ordering designation  (5,00 meters): 3000-U19

 
  ZH Plugs Wiring between plugs
Signal Pin number Wire Color
12 VDC 1 White

1 <-> 1

2 <-> 2

3 <-> 3

4 <-> 4

CAN-High 2 Brown
CAN-Low 3 Green
Ground 4 Yellow

 


 

CAN/Power cable for connecting "KIT"- modules to "BOX"-modules or to 19 inch Racks

CAN/Power cable for connecting "KIT"-modules to "BOX"-modules or to 19 inch Racks

Cable with one CAN plug (ZH plug) and one RJ11 plug (RJ12 4x6) for connecting a "KIT"-housing version of an ELM module to a "BOX"-housing version of a module or to an ELM 19 inch Rack Mount Unit. The cable is for CAN-Bus signal transmission as well as for power supply. Several standard lengths are available. Other lengths on demand.

Ordering designation  (3,00 meters): on inquiry

Ordering designation  (5,00 meters): on inquiry

 

Signal

ZH Plug

Pin number

RJ12 Plug

Pin number

Wire Color

Wiring between plugs

12 VDC 1 1 Yellow

1 <-> 1

2 <-> 2

3 <-> 3

4 <-> 4

CAN-High 2 2 Green
CAN-Low 3 3 Red
Ground 4 4 Black

 


 

Prolongation cable for peripherals

For prolongation of the connection cable of handles, latches, sensors or actors for connecting a "BOX"- housing version of a Module or a 19 inch Rack

 

Ordering designation (2 meters): on inquiry

Ordering designation (5 meters): on inquiry

 

Plug / Jack

 

Pin number Wire Color
1 Green
2 Brown
3 White
4 Yellow

 


 

Y-Sensor Splitter Cable

Y-Actor Splitter Cable

Y-Splitter cables for connecting sensors or actors to 19 inch Rack sockets with 2 sensor inputs or 2 relay outputs

 

Ordering designations: on inquiry

Y-Sensor Splitter Cable

Signal

(sensor inputs at rack socket)

Plug

 

Wiring between plug and jacks A/B

Pin number Wire Color
12 VDC 1 Green

Plug Pin 1 <-> Jack A Pin 1 <-> Jack B Pin 1

Plug Pin 2 <-> Jack A Pin 2 <-> Jack B Pin 4

Plug Pin 3 <->  Jack A Pin 3 <-> Jack B Pin 3

Plug Pin 4 <-> Jack A Pin 4 <-> Jack B Pin 2

Sensor A 2 White
Ground 3 Brown
Sensor B 4 Yellow
Y-Actor Splitter Cable

Signal

(relais at rack socket)

Plug

 

Wiring between plug and jacks A/B

Pin number Wire Color
first contact - 1 1 Green

Plug Pin 1 <-> Jack A Pin 1

Plug Pin 2 <-> Jack A Pin 2

Plug Pin 3 <-> Jack B Pin 1

Plug Pin 4 <-> Jack B Pin 2

first contact - 2 2 White
second contact - 1 3 Brown
second contact - 2 4 Yellow

 


 

3000-U29

Patch-Cable Crossover 2 x RJ45

 

Category 5 Crossover Cable used for the following tasks:

  • Connecting the Communication component of the ELM system directly (that means without a hub or switch) to a Ethernet-LAN socket of a PC/Workstation. The ELM system can be managed over LAN. A Communication component resides on the Communication module as well as on 19 inch Master Racks.

Ordering designation (? meters): 3000-U28

The following table shows the wiring of a CAT5 Crossover Cable and which wires are used.

RJ45 Plugs Wiring between plugs Wires used for connecting to Ethernet-LAN
Pin number Wire Colors
1 Orange/White <-> Green/White

1 <-> 3

2 <-> 6

3 <-> 1

 

 

6 <-> 2

 

8 <-> 7

Transmit+ <-> Receive+
2 Orange <-> Green Transmit- <-> Receive-
3 Green/White <-> Orange/White Receive+ <-> Transmit+
4   (not used)
5   (not used)
6 Green <-> Orange Receive- <-> Transmit-
7   (not used)
8   (not used)

 


 

3000-U29

Patch-Cable Straight-Through 2x RJ45

 

Category 5 Straight-Though Cable used for the following tasks:

  1. Connecting the Communication component of the ELM system to a Ethernet-LAN Hub or Switch. The ELM system can be managed over LAN. A Communication component resides on the Communication module as well as on 19 inch Master Racks.
     

  2. CAN bus chaining for connecting several 10 inch Racks or "BOX"-housing versions of Modules. When connecting "BOX"-Modules, the cable can be used for CAN data transmission as well as for power supply.

Ordering designation: on inquiry

The following table shows the wiring of a CAT5 Straight-Through Cable and which wires are used for CAN bus chaining of 19 inch Racks

RJ45 Plugs Wiring between plugs Wires used for connecting to Ethernet-LAN (A.) Wires used for CAN bus chaining of Racks (B.)
Pin number Wire Color
1 Orange/White

1 <-> 1

2 <-> 2

3 <-> 3

4 <-> 4

5 <-> 5

6 <-> 6

7 <-> 7

8 <-> 8

Transmit (not used)
2 Orange Transmit (not used)
3 Green/White Receive "BOX"-Modules:12VDC
Racks:(not used)
4 Blue (not used) CAN-High
5 Blue/White (not used) CAN-Low
6 Green Receive Ground
7 Brown/White (not used) (not used)
8 Brown (not used) (not used)

 


 

 

3000-U29

RS232-cable

 

Null-modem cable (9 Pin D-SUB Female plugs) used for the following tasks:

  1. Connecting the Communication component of the ELM system to a serial interface of a workstation. Needed for initial configuration of the ELM-System. Administration can also be done over serial connection. A Communication component resides on the Communication module as well as on 19 inch Master Racks.
     

  2. Connecting additional devices with RS232 interface to a Sensor module.

Ordering designation (3 meters): 3000-U29

 
D-SUB Female Plugs

 Wiring between plugs

Wires used for connecting a  Workstation (A.) Wires used for connecting devices to Sensor module (B.)
 Signal DB9 Pin number
DCD (Data Carrier Detect) 1 1 <-> 7+8

2 <-> 3

3 <-> 2

4 <-> 6

5 <-> 5

6 <-> 4

7+8 <-> 1

X <-> X

(not used) (not used)
RD (Receive Data) 2 RD RD
TD (Transmit Data) 3 TD TD
DTR (Data Terminal Ready) 4 (not used) (not used)
SG (Signal Ground) 5 SG SG
DSR (Data Set Ready) 6 (not used) (not used)
RTS (Request To Send) 7 (not used) RTS (optional)
CTS (Clear To Send) 8 (not used) CTS (optional)
RI (Ring Indicator) 9 (not used) (not used)
Shield X Shield Shield